Dalben Tower (9.50)
Key Attributes
Age Group
-+
Area of Use
-
Activity
-
Suitable for
Assembly time
2 fitters each 20 hours, plus lifting gear
(without creating the foundation)
Techincal Specifications
Lifting Device
-
Total Length
7.00 m
Total Width
8.00 m
Total Height
9.50 m
Minimum Space Length
10.50 m
Minimum Space Width
11.50 m
Minimum Space Height
9.50 m
Heaviest Single Piece
-
(Total) Weight
5310.00 kg
Free Height of Fall
2.10 m
Platform Heights
-
Foundations
Foundation 1
4 pieces - 1.00 x 1.00 x 0.50 m volume: 0.50 m3
Foundation 2
3 pieces - 1.00 x 0.40 x 0.40 m volume: 0.16 m3
Foundation 3
1 piece - 1.00 x 0.40 x 0.50 m volume: 0.20 m3
Foundation 4
1 piece - 0.80 x 0.80 x 1.00 m volume: 0.64 m3
Foundation 5
1 piece - 1.25 x 0.90 x 0.40 m volume: 0.45 m3
Foundation 6
-
Assembly
Number of Installers
2 pers.
Assembly Time
20 h
Assembly Details
K&K Dalbenturmananlage consisting of: Dalbenturm (9.50) with tunnel spiral slide 30 ° / 38 ° (5.00 m) and add-on wide slide (2.00 m); Tower hood green / similar to RAL 6029 with wind vane Technical data Floor area: 7.00 x 8.00 m Minimum space: 10.50 x 11.50 m (68 m²) Height: 9.50 m + tower end Platform heights: 1.00 / 2.00 / 3.00 / 4, 00 / 5.00 m Stand post glued wood larch Ø 20 cm with triple wood protection coating , on hot-dip galvanized steel feet Platform floors Triangular wooden platforms , joists laminated larch wood, platform covering Robinia 95 x 30 mm, screwable flange connections on the support posts, ladder access made of stainless steel pipe , rung height 500 mm, including fall protection, between the platforms, glass bead blasted. Protective grille (from 1.00 m platform height) welded construction made of stainless steel tube Ø 21 / 33.7mm, glass bead blasted, from 1.00 m platform height, screwable flange connections on the support posts Tower hood high pressure laminate 15 mm, color green / similar to RAL 6029 Tower end wind vane K&K add-on wide slide, Ah 2.00 m add-on height: 2.00 m seat height: 2.10 m slide inclination : 36 ° slide width : 1.10 m slide plate thickness : 2.5 mm Add-on wide slide, 1.10 m wide, one-piece stainless steel construction, with anti-roll-off fall protection above the single-seat part, particularly low-noise thanks to the trough shape. K&K tunnel spiral slide 30 ° / 38 °, Ah 5.00 m Slide installation height : 5.00 m Seat height: 5.10 m Slide inclination : 30 ° / 38 ° Turn: 360 ° clockwise Tunnel diameter: 0.80 m Slide plate thickness : 2.5 mm Slide segments made of stainless steel, especially low-noise due to the tunnel shape, welded to a three-part slide, which is coiled around a central pylon for transport reasons, including the corresponding connecting flanges to facilitate on-site assembly. For your planning, please note that stainless steel slides are oriented to the north-east due to the possible heating of the slide surface or are in the partial shade of trees. Anchoring Dowelling of the circular base with 2 injection anchor rods made of A4 stainless steel. To protect against damage, the tower is equipped with a lightning rod. Foundations (on site) 4 pcs. 1.00 x 1.00 x 0.50 m 3 pcs. 1.00 x 0.40 x 0.40 m 1 pc. 1.00 x 0.40 x 0.50 m 1 pc. 0.80 x 0.80 x 1.00 m 1 pc. 0.90 x 1.25 x 0.40 m amount of concrete: 3.30 m³ Free fall height 2.10 m The foundation sizes mentioned in this offer correspond to the static requirements for soil types that are moderately difficult to loosen with a permissible soil pressure of at least? R, d = 150 kN / m². In the case of different soil conditions and installation in areas with high wind loads (deviating from German wind zone 2, corresponds to vref = 25.0 m / s) or high snow loads (deviating from German snow load zone 2, corresponds to sk? 0.85 kN / m²), technical changes to the construction of the product required (e.g. insertion of cross braces). This results in additional costs and an extension of the specified delivery time. At the request of the client, Kaiser & Kühne can commission a recognized engineering office to carry out the required static calculation. The resulting costs are to be borne by the client. The client must provide the necessary evidence of the local conditions.
Technical Data
–